in stock#
Brand/ Manufacturer:
Bently NevadaDimensions:
8.3x3.5x3.2cmWeight:
0.3kgCountry of Origin: :
USADescription:
Bently Nevada 190501-99-00-00 Velomitor CT Velocity Transducer
| Mfr. Part Number: |
190501-99-00-00 |
| Manufacturer: |
Bently Nevada |
| Description: |
Bently Nevada 190501-99-00-00 Velomitor CT Velocity Transducer |
| Full Description: | The Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor Piezo-velocity Sensor. |
| Status: |
In stock |
Click to get price :
: plcinfo@mooreplc.com
: +86 18020776786
: mooreplc
Moore Automation Limited is not affiliated with or a distributor for Bently Nevada. The depiction, description, or sale of products featuring names, trademarks, brands, and logos is for identification and/or reference purposes only and does not indicate any affiliation with or authorization by any rights holder.
Product Description:
The 190501-99-00-00 Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor Piezo-velocity Sensor. Its design specifically measures casing vibration velocity on cooling tower and air-cooled heat-exchanger fan assemblies that operate at or above 90 rpm (100 to 300 rpm typical). The Velomitor CT Transducer can measure vibration amplitudes at these frequencies as well as the vibration frequencies generated by the fan motor and speed reducer.
Application:
Cooling Towers: Measuring vibration amplitudes on fan blades, gearboxes, and fan motors to detect structural imbalances, looseness, or gear degradation
Air-Cooled Heat Exchangers (ACHE): Monitoring casing and bearing housing vibrations to protect slow-moving rotating equipment commonly found in petrochemical and refining operations.
Low-Speed Rotating Equipment: Detecting early signs of mechanical malfunctions (e.g., unbalance, misalignment, or blade passing frequencies) before they cause catastrophic failures
Pumps and compressors: Widely used for predictive maintenance of various industrial pumps and compressors.
Frequently Asked Questions (FAQ)
Q:What does the 190501 series monitor?
A:It is primarily used to monitor casing vibration velocity on cooling towers and air-cooled heat-exchanger fan assemblies. It is explicitly designed for slow-rotating machinery operating at or above 90 RPM (typically 100 to 300 RPM).
Q:What is the difference between a standard Velomitor and the 190501 CT?
A:The 190501 CT has a frequency response adjusted to much lower frequencies (starting at 1.5 Hz to 3.0 Hz) compared to a standard Velomitor. This allows the CT sensor to capture the low-speed vibration frequencies generated by large, slow-moving fan motors and speed reducers.
Q:What is the maximum cable length I can use?
A:The transducer supports a maximum cable length of up to 305 m (1,000 ft) without significantly compromising signal integrity.
If you need other brands products like below, please feel free write email to plcinfo@mooreplc.com
You will get Best price and Professional service (24/7)
|
Detailed Parameter |
Part Number:190501-99-00-00 |
|
Connection Option |
MIL-C-5015 connection interface |
|
Agency Approval Option |
No Approvals |
|
Sensitivity |
3.94 mV/mm/s (100 mV/in/s) ±5% |
|
Transverse Response |
Less than 5% of the axial sensitivity |
|
Dynamic Output Impedance |
<400 Ω typical |
|
Operating Temperature |
-40°C to +85°C (-40°F to +185°F) |
|
Storage Temperature |
-40°C to +100°C (-40°F to +212°F) |
|
Shock Limit |
5000 g pk, maximum |
|
ADV151 |
DS200DCFBG1BNC |
FC-TPSU-2430 |
SPS5710 51199929-100 |
|
F3PU20-0N |
DSTD N031 3BSE013335R1 |
FS-TSAO-0220m |
BB174 3BSE003879R1 |
|
F3SP21-0N |
GJR2322600R0100 88UB01A |
FC-TSAO-0220m |
330425-01-CN |
|
AS S9831DB-01 |
IS200EMIOH1ACA |
FC-TSAOH-0220m |
330130-085-03-05 |
|
SD823 |
146055-10-02-00 |
YPH105E YT204001-FC |
9182/20-51-11 |
|
KJ2201X1-JA1 |
1900/55 |
YPK107E YT204001-FY |
IS210AEAAH1BKE |
|
12P3323X022 |
330104-00-05-05-02-05 |
330101-33-66-10-02-05 |
IS210AEPSG1AFC |
|
KJ3202X1-BA1 |
330104-08-14-10-02-05 |
330103-02-04-30-01-00 |
336A4940CTP2 |
|
SLS1508 VS3202 |
330980-71-00 |
33105-02-12-05-02-00 |
PA1M011 |
|
KJ2002X1-CA1 |
57C493 |
330500-07-04 |
3VTVZ590CD001 |
|
KJ4001X1-JA1 |
4454-132 |
330104-01-08-15-02-05 |
DS200DSPCH1A |
|
KJ3001X1-BB1 |
330180-X1-05 |
YPQ101E YT204001-FS |
DS200VPBLG1AEE |
|
12P0550X142 VE4001S2T2 |
330173-00-03-10-02-00 |
YPQ102E YT204001-FT |
IS200EISBH1A |
|
F3RP41-2P/L1 |
SL10.504 |
IS200TRLYH1BGF |
FS-TSDO-0424 |
|
ADCV01 |
CI867AK01 |
IS200ECTBG1A |
FC-TSDO-0424 |
|
KJ3203X1-BA1 |
330104-08-16-10-02-00 |
RCNA-01 |
DS200TCPDG1BEC |
|
12P2506X062 VE4006P2 |
330173-00-04-10-02-00 |
DSTDW130 57160001-YX |
DS200TCQCG1BJF |
It's like having the store come to you!
Quick Quotes :
Receive price & availability FAST from our dedicated customer service team.Delivery :
Expedited, Freight, and International shipping available.
Warranty :
If there's a problem, we'll make it right. Your satisfaction is how we measure success!Returns :
No hassle return policy.Repair :
Our team of engineers are creative problem solvers who understand your challenges.Payment :
Custom Calibration :
You give us the specs and we do the rest.Share this page :
Tweet
Share
Share
Email Us