in stock#
Brand/ Manufacturer:
Bently NevadaDimensions:
3.6x3.1x10cmWeight:
0.38kgCountry of Origin: :
USADescription:
Bently Nevada 190501-20-99-04 Velomitor CT Velocity Transducer
| Mfr. Part Number: |
190501-20-99-04 |
| Manufacturer: |
Bently Nevada |
| Description: |
Bently Nevada 190501-20-99-04 Velomitor CT Velocity Transducer |
| Full Description: | The Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor Piezo-velocity Sensor. |
| Status: |
In stock |
Click to get price :
: plcinfo@mooreplc.com
: +86 18020776786
: mooreplc
Moore Automation Limited is not affiliated with or a distributor for Bently Nevada. The depiction, description, or sale of products featuring names, trademarks, brands, and logos is for identification and/or reference purposes only and does not indicate any affiliation with or authorization by any rights holder.
Product Description:
The 190501-20-99-04 Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor Piezo-velocity Sensor. Its design specifically measures casing vibration velocity on cooling tower and air-cooled heat-exchanger fan assemblies that operate at or above 90 rpm (100 to 300 rpm typical). The Velomitor CT Transducer can measure vibration amplitudes at these frequencies as well as the vibration frequencies generated by the fan motor and speed reducer.
Application:
Power Generation Stations: Used on massive heat-rejection cooling systems to ensure structural integrity and prevent catastrophic fan blade delamination or failure.
Slow-Speed Industrial Pumps: Applied to water and wastewater treatment plants to monitor casing vibrations on massive, low-RPM pump systems.
Petrochemical and Refining Plants: Implemented on critical cooling infrastructure where explosive gas protection is required, leveraging the -04 multiple agency safety approvals option
Cooling Tower Fan Assemblies: Monitored to detect faults like unbalance, misalignment, or mechanical looseness in large industrial cooling towers.
Frequently Asked Questions (FAQ)
Q:What is its frequency response?
A:The device has an adjusted downward range to catch slow-moving fans. It delivers ± 1.0 dB accuracy from 3.0 Hz to 900 Hz and ± 3.0 dB from 1.5 Hz to 1.0 kHz. This allows it to monitor fans running as low as 90 rpm.
Q:Can it be mounted in any orientation?
A:Yes. It can be installed at any mounting angle or orientation without affecting performance
Q:What is the maximum supported cabling length?
A:It supports a maximum cable run up to 305 meters (1,000 feet) back to the monitoring system
If you need other brands products like below, please feel free write email to plcinfo@mooreplc.com
You will get Best price and Professional service (24/7)
|
Detailed Parameter |
Part Number:190501-20-99-04 |
|
Mounting Hardware Option |
Adapter, 3/8-in 24 to 3/8-in 18 NPT |
|
Connection Option |
Unit with included 32-foot cable |
|
Sensitivity |
3.94 mV/mm/s (100 mV/in/s) ±5% |
|
Temperature Sensitivity |
-8% to +5% typical over the operating temperature range |
|
Transverse Response |
Less than 5% of the axial sensitivity |
|
Amplitude Linearity |
±2% to 63.5 mm/s pk (2.5 in/s pk) |
|
Dynamic Output Impedance |
<400 Ω typical |
|
Operating Temperature |
-40°C to +85°C (-40°F to +185°F) |
|
Storage Temperature |
-40°C to +100°C (-40°F to +212°F) |
|
Shock Limit |
5000 g pk, maximum |
|
ADV151 |
DS200DCFBG1BNC |
FC-TPSU-2430 |
SPS5710 51199929-100 |
|
F3PU20-0N |
DSTD N031 3BSE013335R1 |
FS-TSAO-0220m |
BB174 3BSE003879R1 |
|
F3SP21-0N |
GJR2322600R0100 88UB01A |
FC-TSAO-0220m |
330425-01-CN |
|
AS S9831DB-01 |
IS200EMIOH1ACA |
FC-TSAOH-0220m |
330130-085-03-05 |
|
SD823 |
146055-10-02-00 |
YPH105E YT204001-FC |
9182/20-51-11 |
|
KJ2201X1-JA1 |
1900/55 |
YPK107E YT204001-FY |
IS210AEAAH1BKE |
|
12P3323X022 |
330104-00-05-05-02-05 |
330101-33-66-10-02-05 |
IS210AEPSG1AFC |
|
KJ3202X1-BA1 |
330104-08-14-10-02-05 |
330103-02-04-30-01-00 |
336A4940CTP2 |
|
SLS1508 VS3202 |
330980-71-00 |
33105-02-12-05-02-00 |
PA1M011 |
|
KJ2002X1-CA1 |
57C493 |
330500-07-04 |
3VTVZ590CD001 |
|
KJ4001X1-JA1 |
4454-132 |
330104-01-08-15-02-05 |
DS200DSPCH1A |
|
KJ3001X1-BB1 |
330180-X1-05 |
YPQ101E YT204001-FS |
DS200VPBLG1AEE |
|
12P0550X142 VE4001S2T2 |
330173-00-03-10-02-00 |
YPQ102E YT204001-FT |
IS200EISBH1A |
|
F3RP41-2P/L1 |
SL10.504 |
IS200TRLYH1BGF |
FS-TSDO-0424 |
|
ADCV01 |
CI867AK01 |
IS200ECTBG1A |
FC-TSDO-0424 |
|
KJ3203X1-BA1 |
330104-08-16-10-02-00 |
RCNA-01 |
DS200TCPDG1BEC |
|
12P2506X062 VE4006P2 |
330173-00-04-10-02-00 |
DSTDW130 57160001-YX |
DS200TCQCG1BJF |
It's like having the store come to you!
Quick Quotes :
Receive price & availability FAST from our dedicated customer service team.Delivery :
Expedited, Freight, and International shipping available.
Warranty :
If there's a problem, we'll make it right. Your satisfaction is how we measure success!Returns :
No hassle return policy.Repair :
Our team of engineers are creative problem solvers who understand your challenges.Payment :
Custom Calibration :
You give us the specs and we do the rest.Share this page :
Tweet
Share
Share
Email Us