in stock#
Brand/ Manufacturer:
Bently NevadaDimensions:
6.7x2.8x2.4cmWeight:
0.12kgCountry of Origin: :
USADescription:
Bently Nevada 177230-01-02-CN 16925-16 Seismic Transmitter
| Mfr. Part Number: |
177230-01-02-CN 16925-16 |
| Manufacturer: |
Bently Nevada |
| Description: |
|
| Full Description: |
The 177230 Seismic Transmitter incorporates robust CM for reliability and implements an industry-standard 4 to 20 mA loop-powered transmitter. |
| Status: |
In stock |
Click to get price :
: plcinfo@mooreplc.com
: +86 18020776786
: mooreplc
Moore Automation Limited is not affiliated with or a distributor for Bently Nevada. The depiction, description, or sale of products featuring names, trademarks, brands, and logos is for identification and/or reference purposes only and does not indicate any affiliation with or authorization by any rights holder.
Product Description:
The Bently Nevada 177230-01-02-CN is a loop-powered seismic vibration transmitter paired with a 16925-16 non-armored connection cable. This industrial sensor system translates physical machinery vibration into a standard 4–20 mA current loop signal, allowing direct integration into PLCs, DCSs, or SCADA systems for asset condition monitoring.The 177230 Seismic Transmitter is a simple, loop-powered device that can be quickly and easily installed. It can be integrated into your programmable logic controller (PLC) or controls system linked to a plant asset condition monitoring solution. Its simple design reduces training, maintenance, and service costs.
Application:
Oil & Gas / Petrochemical: Installed on off-site pumps, refinery utility fans, and auxiliary fluid transfer stations.
Power Generation: Used for balance-of-plant (BOP) machinery such as water feed pumps, draft fans, and cooling tower equipment.
Water & Wastewater: Monitors massive water distribution pumps, sewage aerators, and treatment plant blowers.
Pulp, Paper, & Chemical Manufacturing: Deployed across conveyor drives, agitators, and process machinery in corrosive or humid environments.
Frequently Asked Questions (FAQ)
Q:Where is this transmitter typically installed?
A:This sensor is ideal for non-critical or general machine assets where specialized rack-based machinery protection systems are cost-prohibitive. It is mounted directly onto the bearing housings of industrial assets like pumps, electric motors, small fans, and blowers to track overall casing vibration velocity.
Q:Can this unit operate in high-humidity conditions?
A:Yes. The transmitter casing is completely sealed and designed to operate reliably in environments up to 100% relative humidity as long as the housing remains completely non-submerged.
Q:What type of output does the transmitter provide?
A:It provides a 4-20 mA current output proportional to the asset's peak vibration levels. The current loop is driven from Pin A to Pin B of its integrated interface, which can feed directly into programmable logic controllers (PLCs), distributed control systems (DCSs), or SCADA platforms.
If you need other brands products like below, please feel free write email to plcinfo@mooreplc.com
You will get Best price and Professional service (24/7)
|
Detailed Parameter |
Part Number:177230-01-02-CN 16925-16 |
|
Measurement Range |
0 – 25.4 mm/s (0 – 1.0 in/s) |
|
Frequency |
3 Hz to 1 kHz (180 to 60 kcps) peak |
|
Length in feet |
16 feet |
|
Excitation Voltage |
12 to 30 Vdc (Current limited to 40 mA) |
|
Transverse Sensitivity |
Less than 5% of sensitivity |
|
Output Signal |
4 to 20 mA Current Loop from Pin A to Pin B |
|
Sensitivity |
10.2 mV/m/s2 (100 mV/g) ± 20% |
|
Linearity |
± 1% of Full Scale |
|
Operating Temperature |
-40°C to +85°C (-40°F to +185°F) |
|
ADV151 |
DS200DCFBG1BNC |
FC-TPSU-2430 |
SPS5710 51199929-100 |
|
F3PU20-0N |
DSTD N031 3BSE013335R1 |
FS-TSAO-0220m |
BB174 3BSE003879R1 |
|
F3SP21-0N |
GJR2322600R0100 88UB01A |
FC-TSAO-0220m |
330425-01-CN |
|
AS S9831DB-01 |
IS200EMIOH1ACA |
FC-TSAOH-0220m |
330130-085-03-05 |
|
SD823 |
146055-10-02-00 |
YPH105E YT204001-FC |
9182/20-51-11 |
|
KJ2201X1-JA1 |
1900/55 |
YPK107E YT204001-FY |
IS210AEAAH1BKE |
|
12P3323X022 |
330104-00-05-05-02-05 |
330101-33-66-10-02-05 |
IS210AEPSG1AFC |
|
KJ3202X1-BA1 |
330104-08-14-10-02-05 |
330103-02-04-30-01-00 |
336A4940CTP2 |
|
SLS1508 VS3202 |
330980-71-00 |
33105-02-12-05-02-00 |
PA1M011 |
|
KJ2002X1-CA1 |
57C493 |
330500-07-04 |
3VTVZ590CD001 |
|
KJ4001X1-JA1 |
4454-132 |
330104-01-08-15-02-05 |
DS200DSPCH1A |
|
KJ3001X1-BB1 |
330180-X1-05 |
YPQ101E YT204001-FS |
DS200VPBLG1AEE |
|
12P0550X142 VE4001S2T2 |
330173-00-03-10-02-00 |
YPQ102E YT204001-FT |
IS200EISBH1A |
|
F3RP41-2P/L1 |
SL10.504 |
IS200TRLYH1BGF |
FS-TSDO-0424 |
|
ADCV01 |
CI867AK01 |
IS200ECTBG1A |
FC-TSDO-0424 |
|
KJ3203X1-BA1 |
330104-08-16-10-02-00 |
RCNA-01 |
DS200TCPDG1BEC |
|
12P2506X062 VE4006P2 |
330173-00-04-10-02-00 |
DSTDW130 57160001-YX |
DS200TCQCG1BJF |
It's like having the store come to you!
Quick Quotes :
Receive price & availability FAST from our dedicated customer service team.Delivery :
Expedited, Freight, and International shipping available.
Warranty :
If there's a problem, we'll make it right. Your satisfaction is how we measure success!Returns :
No hassle return policy.Repair :
Our team of engineers are creative problem solvers who understand your challenges.Payment :
Custom Calibration :
You give us the specs and we do the rest.Share this page :
Tweet
Share
Share
Email Us