The HONEYWELL 05701-A-0361 Engineering Card is designed as a dedicated engineering interface for the Honeywell System 57 platform, allowing maintenance personnel to configure, monitor, and service installed control cards from a centralized location. As part of the System 57 architecture, the module simplifies commissioning procedures while improving operational efficiency and system reliability.
Definition
The HONEYWELL 05701-A-0361 is an Engineering Card for the Honeywell System 57 gas detection control system. Installed in the dedicated engineering slot of the rack, it provides a common interface for commissioning, configuration, diagnostics, and routine maintenance of installed control cards. The module also supports communication, system clock management, and external engineering access through an RS232 interface.
Model Features
1. Centralized Engineering Interface
The 05701-A-0361 provides a unified engineering interface for all compatible control cards installed in a System 57 rack. Engineers can access operating parameters and perform configuration tasks without interacting with each control card individually.
2. Comprehensive Commissioning Functions
The engineering card supports essential commissioning operations, including zero adjustment, span calibration, alarm setpoint verification, alarm testing, sensor monitoring, and system clock configuration. These functions help reduce installation time and simplify routine maintenance.
3. Integrated Communication and Diagnostics
The module incorporates backplane serial communication control, self-diagnostic capabilities, and an RS232 engineering interface for connecting external computers, printers, or engineering keys. This design facilitates troubleshooting and system validation during maintenance activities.
4. User-Friendly Front Panel Design
The front panel features tactile push buttons for navigation and function selection, along with LED indicators that display rack power and engineering status. An engineering key can be used to unlock protected configuration functions when authorized.
5. Industrial-Grade Electrical Design
Operating from an 18–32 VDC power supply with a typical power consumption of approximately 1.5 W, the 05701-A-0361 is designed for continuous operation in industrial gas monitoring environments. Its compact form factor allows easy installation within standard System 57 racks.
Detailed Parameter
Part Number:05701-A-0361
Power supply
18-32V DC
Power consumption
Approx. 1.5W
Operating temperature
-20°C to +60°C (or -40°C to +85°C)
Communication interface
RS232 / RS485
Card Slot Width
1 inch (2.54 cm) Standard Euro Card Format
Output Compliance Range
40V
Signal Range
0 - 25mA.
Power Consumption
1.5W (typical)
The difference between 05701-A-0325 and 05701-A-0361
Specification / Feature
05701-A-0325 DC Input Card
05701-A-0361 Engineering Card
Primary Function
System infrastructure and power routing.
Setup, calibration, and maintenance interface.
Core Duty
Receives and distributes external 24V DC power to all active control cards in the sub-rack.
nterrogates individual channels to change alarm set-points and configure system options.
Interface Elements
2-part TB1 terminal blocks and a system fuse.
system fuse.Tactile front panel buttons for system adjustments.
Time Tracking
None (Passive infrastructure piece).
Features an onboard Real-Time Clock (RTC) to log dates and prompt for calibration due schedules.
Security Layer
Reverse polarity and overcurrent protection.
Software-driven Security Password Protection to prevent unauthorized tampering.
Typical Quantity
Standard requirement for each running sub-rack.
Typically one module per separate rack setup for local maintenance.
Frequently Asked Questions
Can the 05701-A-0361 be removed without shutting down the entire rack?
The Engineering Card is mechanically isolated in its own slot and can be physically extracted without disturbing adjacent Channel Control Cards or field wiring connections. However, the manual specifies that DC power must be removed from the rack before any card insertion or removal. Attempting hot-swapping may disrupt backplane communications and corrupt active configuration sessions.
What does the Unlocked red LED indicate during normal operation?
When the Unlocked LED is illuminated, the Engineering Card is in maintenance mode, allowing parameter modification, channel calibration, and relay logic configuration through either the front-panel buttons or the RS232 interface. During standard monitoring operations, this LED should remain off to prevent unauthorized or accidental system changes. The locked/unlocked state is toggled through the engineering interface software or specific button sequences.
What are the RS232 interface requirements for PC connection?
The RS232 port on the Engineering Card connects to an external IBM-compatible PC running Honeywell's engineering interface software. A standard DB9 serial cable is used with default communication parameters as defined in the system manual. Cable length should conform to RS232 standards—typically limited to 15 meters—to ensure reliable data transmission during bulk parameter uploads, historical data retrieval, or firmware maintenance operations.
Are optional modules hot-swappable?
The Modbus, Event Printing, and Master Alarm Update modules are daughterboards that plug directly into the Engineering Card's expansion socket and draw power from the rack backplane. Installation or removal requires complete power-down of the rack via the DC Input Card. The Power On LED must be fully extinguished before handling these modules to prevent damage to the interface circuitry on both the Engineering Card and the optional module.
Hot Selling Recommendations
Bently Nevada 330104-00-09-10-01-00
Bently Nevada 330104-00-09-10-01-00
Bently Nevada 330101-00-16-10-11-00
Bently Nevada 330103-00-13-50-12-00
Bently Nevada 330103-00-16-50-12-00
Bently Nevada 330103-00-22-50-12-00
Bently Nevada 330105-02-12-05-12-00
Bently Nevada 330901-05-45-05-11-05
ABB 3BES004725R1 DSTD196
ABB HIEE300725R1 UAC317AE V1
ABB HIEE300686R1 UFC092A V1